Falcon U109635-02 Double Oven User Manual


 



Australia
Support the weight of the door and remove the screw
nearest the hinge pin. Swing the hinge up and away from
the hinge pin on the door.
Lift the door away from the bottom hinge.
Re-assemble in reverse order.
When replacing the door, ensure that the nylon hinge bush
is in position between the hinge pin and the hinge bracket
at the both the bottom and top.

Remove the two plastic blanking plugs from the door
handles. Remove the four 4mm Hex headed screws holding
the handle to the door with the hexagon key tool. Remove
two screws from the top edge, and two from the bottom
edge, of the door:
Remove the outer door panel. Fit the door handle to the
new panel. Fit the plastic blanking plugs to the fixing holes.

Fit the panel to the door. If replacing the outer panel on the
right hand door (with the Thermodial) take care to make
sure that the sensor of the Thermodial is sealed to the door
by the rubber grommet:
Re-assemble in reverse order.
 
Remove the outer door panel (see section 15). Remove
screws ‘B’ holding the catch assembly to the inner door
panel. Fit the new catch and re-assemble in reverse order.
Verify that the door operation is correct.

Open the Main oven door, slacken off the locknut at the
base of keep, and screw in or out as required until the
required fit is obtained:
Retighten the locking nut.

Remove the oven door (see section 14). Lay the door face
down on a suitable surface and remove the two screws
from the bottom edge of door and the two screws from
the inside face of the door.
Remove the outer door panel. Remove the door handle
by unscrewing the two screws.
Remove the two cross-headed screws holding the door
handle fixing bracket to the door panel. Fit the door
handle bracket and the door handle to the new panel.
Fit the panel to the door and re-assemble in reverse
order.

Remove the control panel (see section 2). Remove the
plinth (three screws) and the central vertical cover (five
screws). Prize the retaining clip off the magnet unit.
Fit the new unit and retaining clip, and re-assemble in
reverse order. Verify that the door operation is correct.

Open the oven door. The seal is held in place by small hooks
on the rear face. At the corner, pull the seal diagonally away
from the door centre until that hook is released. Proceed to
the next hook and release it in a similar way, and so on.