ALTERNATIVE PIPING METHODS TO CONNECT
APPLIANCE TO GAS SUPPLY A TRAINED
SERVICE MAN OR GAS APPLIANCE INSTALLER
MUST MAKE THE GAS SUPPLYCONNECTION.
Leak testing of the appliance shall be conducted
by the Installer according to the Instructions
given.
Unless prohibited by local codes or ordinances, a new
A.G.A. - Certified, flexible metal appliance connector
may be used to connect this appliance to its gas
supply. The connector must have an internal diameter
not less than nominal 1/2” NPT pipe and be no more
than 5 feet in length. A 1/2” NPT x 1/2” flare union
adapter is required at each end of the flexible
connector.
If a flexible connector is used assure that both the
appliance pressure regulator and manual shut-off
valve are joined solidly to other permanent hard piping
(either gas supply or the appliance manifold) so as to
be physically stationary. See figure 13.
CAUTION
Do not attempt to attach the flexible connector directly
to an external pipe thread.
Connection requires flare union adapters.
For Massachusetts Installations:
1. Shut-off valve must be a "T" handle gas cock.
2. Flexible gas connector must not be longer than 36
inch.
3. Not approved for installation in a bedroom or a
bathroom unless unit is direct vent.
MANIFOLD
ENTRANCE
GASKET
GASKET
FLARE
UNION
ADAPTOR
FLARE UNION
ADAPTOR
1/2" NPT
PIPE NIPPLE
ELBOW
1/2" NPT
PIPE NIPPLE
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
GAS
SHUT-OFF
VALVE
GAS
SHUT-OFF
VALVE
FLEXIBLE
APPLIANCE
CONNECTOR
5 FT. MAX
(1.52 m) MAX
()
FLEXIBLE
APPLIANCE
CONNECTOR
5 FT. MAX
(1.52 m) MAX
()
FLARE
UNION
ADAPTOR
FLARE
UNION
ADAPTOR
FLARE
UNION
ADAPTOR
APPLIANCE
PRESSURE REGULATOR,
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)
APPLIANCE
PRESSURE
REGULATOR,
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)
0
1
3
Figure 13.