Installation instructions
Connecting the appliance to NATURAL or TOWN GAS
1
If not already fitted, fit the NATURAL/TOWN GAS hose holder on the inlet pipe, making sure that
you place the sealing washer between them (as shown in Fig. 5a).
2
Connect the appliance to the gas supply using a suitable rubber hose (internal diameter 13 mm).
The hose must comply with the applicable local regulations and be of the correct construction
for the type of gas being used.
3
Make sure that the hose is tightly and securely fitted at both ends.
4
Use a standard hose clamp (not supplied) to fasten the hose.
Connecting the appliance to LPG
1
If not already fitted, fit the LPG adaptor on the inlet pipe, making sure that you place the sealing
washer between them (as shown in Fig. 5a).
Important!
The LPG hose holder is formed by screwing the LPG hose adaptor into the bottom end of the NATURAL/
TOWN GAS hose holder, (with the sealing washer placed in between them).
2
Connect the cooktop to the gas supply using a suitable rubber hose (internal diameter 8 mm).
The hose must comply with the applicable local regulations and be of the correct construction
for the type of gas being used.
3
Make sure that the hose is tightly and securely fitted at both ends.
4
Use a standard hose clamp (not supplied) to fasten the hose.
5
Install a gas pressure regulator.
Important!
To comply with applicable local regulations, a gas pressure regulator (conforming to the current local
regulations) must be installed when connecting the appliance to an LPG cylinder.
When connecting the appliance to the gas supply with a rubber hose, make sure that
the hose is as short as possible, without twists or kinks.
the hose is not longer than 750 mm (or refer to applicable local regulations) and does not come
into contact with sharp edges, corners or moving parts. Use a single rubber hose only; never
connect the appliance with more than one rubber hose.
the hose is not under tension, twisted, kinked, or too tightly bent, neither while the appliance is
in use nor while it is being connected or disconnected.
the hose does not come into contact with any part of the appliance with a surface temperature
of 70°C or above (or refer to applicable local regulations).
the hose is not subject to excessive heat by direct exposure to flue products or by contact with
hot surfaces.
the hose can easily be inspected along its entire length to check its condition.
the hose is replaced at the printed due date or if it shows signs of wear or damage, and replaced
regardless of its condition after a maximum of three years.
you inform the customer that the gas cylinder valve or the gas supply valve immediately by the
appliance should be closed when the appliance is not in use.
you inform the customer that the hose should not be subjected to corrosion by acidic cleaning
agents.