Fisher & Paykel CG733 Cooktop User Manual


 
15
the flexible hose is not longer than 2000 mm (or refer to applicable local regulations) and does
not come into contact with sharp edges, corners, or moving parts, as these may cause abrasion.
Use a single flexible hose only; never connect the appliance with more than one flexible hose.
the flexible hose can easily be inspected along its entire length to check its condition; if it has an
expiry date, it should be replaced before that date.
if using a flexible hose which is not entirely made of metal, make sure that it does not come into
contact with any part of the cooktop with a surface temperature of 70
o
C or above (or refer to
applicable local regulations).
the rigid pipe or flexible hose is replaced if it shows signs of damage.
the flexible hose is not subject to excessive heat by direct exposure to flue products or by
contact with hot surfaces.
a gas pressure regulator, in compliance with the applicable local regulations, is installed when
connecting to an LPG cylinder.
the socket into which the plug of the flexible hose fit is permanently attached to a firmly fixed
gas installation pipe and is positioned so that the hose hangs freely downwards.
the plug of the flexible hose is accessible after installation, so that it can be disconnected for
service or removal.
you inform the customer that the gas cylinder valve or the gas supply valve immediately by the
cooker should be closed when the appliance is not in use.
you inform the customer that the rigid pipe or flexible hose should not be subjected to corrosion
by cleaning agents.
After connecting the appliance to the gas supply, make sure that you
check the piping and connections using a soapy solution. The presence of bubbles indicated a
leak. Tighten or replace connectons as appropriate, then recheck for leaks.
Important!
Do not use any naked flame to check for leaks.
check whether the injectors are correct for the type of gas being used. If not, follow the
instructions under “Converting the cooktop to a different gas type”.
replace the sealing washer/s on the slightest sign of deformation or imperfection. The sealing
washer/s is/are the part/s which guarantee/s a good seal in the gas connection.
Testing operation
The operation of the appliance MUST be tested before leaving. Turn on the gas and light each
burner. Check for a well-defined blue flame without any yellow tipping. If any abnormailty is
evident, check that the burner cap is located properly and the injector nipple is aligned correctly.
Check the minimum burner setting by quickly rotating the burner knobs from the maximum
to the minimum position: the flame must not go out. If the adjustment is required, see section
‘Adjusting a burner’s minimum gas rate setting’ following.
If satisfactory performance cannot be obtained, check the installation and notify the local gas
supply authority of a gas supply problem, or if it is an appliance problem, Customer Care should
be called to obtain the nearest authorised Service Agent.