Fisher & Paykel CMOH30SS Microwave Oven User Manual


 
34 E
CLEANING AND CARE
CHARCOAL FILTER
The Charcoal Filter is used for non-vented, re-circulated installations. The lter should be changed every
6 to 12 months depending on use.
To initially install the Charcoal Filter:
1. Disconnect power to the oven at the circuit
breaker panel or by unplugging.
2. Remove 3 screws that secure louver.
3. Remove louver by inserting at edge screw-
driver over each tab, depressing the tab down
and moving the louver away from unit.
4. Pull louver away from the oven.
5. Remove 2 screws that cover the sensor duct
cover.
6. Remove the sensor duct cover.
7. Insert the Charcoal Filter by sliding into position
on support tabs.
8. Reattach sensor duct cover and secure with
2 screws.
9. Push louver back into place and gently snap
tabs into place by hand. Replace the 3 screws to
secure louver.
To change/replace the Charcoal Filter:
1. Disconnect power to the oven at the circuit
breaker panel or by unplugging.
2. Remove 3 screws that secure louver.
3. Remove louver by inserting at edge screw-
driver over each tab, depressing the tab down
and moving the louver away from unit.
4. Pull louver away from the oven.
5. Remove 2 screws that cover the sensor duct
cover.
6. Remove the sensor duct cover.
7. Remove old Charcoal lter; discard.
8. Slide replacement Charcoal Filter into position
on support tabs.
9. Reattach sensor duct cover and secure with
2 screws.
10. Push louver back into place and gently snap
tabs into place by hand. Replace the 3 screws
to secure louver.
Note: Replacement Charcoal Filter can be purchased from Fisher and Paykel. Order part number 247890.
Louver
Oven light
Charcoal filter
Screw
Top tab
Bottom tab
Screw
Screw
Charcoal Filter
Sensor duct cover
Charcoal filter