Fisher & Paykel OR90SDBSI Cooktop User Manual


 
10
Installation instructions
Connecting the power supply cable
Important!
This cooker must be connected to the electricity supply only by an authorised person.
To connect the power supply cable to the cooker, it is necessary to:
1 Unhook the terminal board cover by inserting a screwdriver into the two hooks ‘A’ (fig. 11).
2 Unscrew the screw ‘D’ and open completely the cable clamp ‘E’ (figs. 13).
3 Position the U bolts ‘F’ onto terminal board ‘G’ (figs. 13) according to the diagrams in fig. 12.
4 Connect the phase, neutral and earth wires to terminal board ‘G’ according to the diagrams in
figs. 12 - 13.
5 Strain the feeder cable and block it with cable clamp ‘E’ (by screwing screw ‘D’).
6 Close the terminal block cover (check the two hooks ‘A’ are correctly hooked).
Important!
To connect the power supply cable DO NOT unscrew the screws fixing the cover plate behind the terminal
block.
WARNING: If the power supply cable is damaged, it must be replaced only by an authorised service agent in
order to avoid a hazard.
Voltage and power consumption
220-240/380-415 V 3N~ 50/60 Hz 11080 W (diversity not applied)
A
PE
N (L2)
L
1
220-240 V
1
2
3
4
5
1
2
3
4
5
PE
380-415 V 2N
N
L1
L2
1
2
3
4
5
PE
380-415 V 3N
N
L1
L3
L2
Fig. 11 Terminal block Fig. 12 Connection diagrams