Frigidaire PL36PC50EC Ventilation Hood User Manual


 
- 7 -
INSTALL THE HOOD
Fix the hood to the support frame with (6) 3.9x9.5mm mounting screws and (2)
serrated washers.
CONNECT DUCTWORK
(DUCTED HOODS ONLY)
1. Use 6" round metal duct to connect the discharge collar on the hood to the
ductwork above.
2. Use duct tape to make all joints secure and air tight.
3. Remove the temporary retaining screw from the lower flue and set it in place on
the hood.
6” ROUND METAL
DUCT
RETAINING
SCREW
FIG.13
FIG.14
MOUNTING SCREWS
(3.9x9.5mm)
SERRATED
WASHERS
INSTALL FILTERS
(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filter, push in on the metal latch tab and tilt filter
downward to remove.
2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress
the metal latch tab, push filter into position and release. Make sure filter is
securely engaged after installation.
NOTE: Prior to use, remove protective film from the filter frame.
(NON-DUCTED HOODS ONLY)
1. To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter
down to disengage the rear filter tabs.
2. To install the CHARCOAL filter, align the rear filter tabs with slots in the hood.
Push the filter up into place until the front latch snaps securely into the slot.
Make sure the filter is securely engaged after assembly.
3. Install GREASE filter after charcoal filter is installed.
GREASE
FILTERS
TABS
LATCH
NON-DUCTED
RECIRCULATION
FILTER
FIG. 15
FIG. 16