Frymaster *8196329* Fryer User Manual


 
YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 5: FILTRATION
5-4
9.
Reinstall the hold-down ring. Ensure filter
paper is properly aligned under the hold-down
ring. Press the filter paper into place with the
hold-down ring, ensuring the paper laps against
the walls of the filter pan.
10. Sprinkle 1 cup (8 ounces/227 grams) of filter
powder evenly over the paper.
Use a measuring
cup or scoop to evenly distribute filter powder
over the filter sheet.
11. Replace the crumb screen. Ensure crumb
screen is cleaned throughout the workday.
12. Return pan cover to the filter pan.
13. Return filter pan to fryer cabinet, ensuring that
the two drainpipe extensions are directly over
the opening in the filter pan cover.
5.3 Filter Operations
NOTE: When left and right are indicated, refer to the operator’s left and right.
DANGER
Draining and filtering of cooking oil or shortening must be accomplished with care to
avoid a serious burn caused by careless handling. The oil to be filtered is at or near
350°F (177°C). Ensure all hoses are connected properly and drain handles are in
their proper position before operating any switches or valves. Wear all appropriate
safety equipment when draining and filtering oil.