YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 5: FILTRATION
5-8
5.3 Filter Operations (cont.)
6. Close the red drain valve by pushing the handle to the right until it stops. The fryer will not operate
unless the computer senses a closed drain microswitch circuit. Leave the oil return handle (yellow
label) open to allow pump to run and frypot to fill with filtered oil.
7. When filtering is complete:
• Rear Flush Oil Return: Allow the filter to
pump bubbles into the fryer for 15-30 seconds
to ensure the oil return lines are clear of oil.
• Over-the-top Oil Return: Allow the faucet to
sputter for 15-30 seconds to ensure the oil
return lines are clear of oil.
8. Turn off the filter by turning the oil return handle to the left, into the CLOSED position. This
closes the oil return valve under the filtered frypot and stops the filter pump motor.
Empty contents of the crumb screen
into a fireproof container immediately
after filtering is complete.
DANGER
The crumb tray in fryers equipped with a
filter system MUST
be emptied into a
fireproof container at the end of frying
operations each day. Some food particles
can spontaneously combust if left
soakin
g
in oil.