Frymaster *8196329* Fryer User Manual


 
YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2-2
2.3 Principles of Operation
The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio
for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light.
Internal diffusers slow the flame as it goes through the burner tube. This slow, turbulent flame
increases heat transfer to the walls of the tubes to heating the oil more efficiently.
2.4 Rating Plate
This is attached to the inside of the front door panel. Information provided includes the model and
serial number of the fryer, BTU/hr (kW/hr) input of the burners, outlet gas pressure in inches W.C.
(mbars), and whether the unit has natural (G20/25) or propane (G31) gas orifices.
2.5 Pre-Installation
DANGER
This appliance is equipped with a three-prong (grounding) plug for your protection
against electrical shock and must be plugged directly into a properly grounded
three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding
prong on this plug.
A. General: Only licensed personnel should install any gas-fired equipment.
1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for
safety and ease of future service.
2. The Frymaster YSCFH18G gas fryers require 120 volts (AC) 60-cycle electrical service
for U.S./Canada/Mexico installations. Fryers are equipped with a 16-3 SJT grounded
flexible power cord for a direct connection to the power supply. Amperage draw for each
unit depends on the accessories supplied with the unit. See detailed instructions packaged
with the fryer line-up.
DANGER
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline
at 1-800-551-8633.