Frymaster 8196339 Fryer User Manual


 
4-7
4.7 CM7 Button Description and Functions
4.7.1 Navigation Buttons
The menu on the CM7 uses 34and tu buttons to
navigate the various menus and submenus (see Figure 1).
Figure 1
When programming, the left screen shows a menu or submenu item. The right screen is for data
entry. Data is entered with alpha-numeric characters, scrolling through lists or by toggling between
choices.
During programming, if a button is not pushed within one minute, the computer returns to operation
mode.
4.7.2 Temperature and Unlock Buttons
The TEMP button (see Figure 1), if pressed once while the fryer is on, displays current vat
temperature on both sides. If the TEMP button is pressed twice, it shows the setpoint temperatures
of the vats. If the fryer is off, the display shows the current versions of software. The UNLOCK
button (see Figure 1), if pressed once while the fryer is on, shows the recovery time for each vat
from the last test. Recovery displays the time required for the fryer to raise the temperature of the oil
50°F (28°C) between 250°F (121°C) and 300°F (149°C). If the fryer is off, pressing the unlock
button once allows access to Program Mode; pressing twice allows access to Manager Mode and
pressing three times allows access to Tech Mode.
4.7.3 Cook Cycle and Selection Buttons
The 9 and 8 buttons are dual-function buttons shared
with the number
1 and 2 buttons. They are located directly
below the LED displays (see Figure 2). Use these buttons
to select or cancel functions. The
8 button is used to back
out of submenus.
Figure 2
4.7.4 Melt Cycle and Cooking Displays
Once the computer is switched on, it displays CYCL during melt cycle until the oil reaches 180°F
(82°C). The display changes to LOW TEMP until setpoint is reached. Once setpoint is reached,
the computer will display dashed lines or the product name