Frymaster 8196345 Fryer User Manual


 
1-6
Pressure
(mbar)
Gas
Single
Vat
Natural Gas Lacq
(G20) under 20 mbar
7
Natural Gas Gronique
*
(G25) under 25 mbar
10
Natural Gas Gronique
(G25) under 20 mbar
10
Butane/Propane
(G30) at 28/30 or 50 mbar
17
Propane
(G31) under 37 or 50 mbar
20
CE Standard
Burner Manifold Gas Pressures
* Belgian G25 = 7,0 mbar
Gas Pressure
Natural
3" W.C.
0.73 kPa
Propane
8.25" W.C.
2.5 kPa
Non-CE Standard
Burner Ma nifold Ga s Pre ssures
6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the
correct pressure.
Non-CE
Valve
CE
Valve
GAS VALVE REGULATOR CAP
7. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove
the fitting from the pressure tap hole and reinstall the pressure tap plug.