Operational and Diagnostic Programming Codes
8-1
Entry Codes
All codes are preceded by this sequence:
Press
. Computer displays OFF.
Press programming key in Frymaster logo. Code appears in left display.
Use product keys to enter access codes.
Default settings
Enter1651: Computer reloads default settings.
Recovery Time
Enter1652: Computer displays recovery time.
Heads Cooked
Enter 1653: Computer displays heads cooked.
Heads cooked from last filter
Enter 1654: Computer displays heads cooked since last filtering.
Computer Setup
Enter 1656: Set up computer.
Clear Head Counter
Enter 1657: Computer clears head count.
Program Global Filter Count
Enter 1658: Used to enter total cook cycles before computer calls for filtering.
Programming
Enter 1650: Used to enter programming instructions.
Clear Filter Prompt
Enter 1111: Used to clear a filter prompt on fryers not equipped with filter
systems. Church’s computers use 1111 to delay filtering.
Diagnostic
Hints
The CM4-S
records recovery
time, which is the
time required for
the fryer to raise
the temperature of
the oil from 275°F
to 325°F. This
information is
accessible with a
programming
code. Other useful
measures, such as
total heads cooked
and heads cooked
since last filtering,
are also
accessible.
12345 6 7 8 9 10
CM4-S
12345 678910
Programming
button