5
5. Rotate the tray stabilizer latch upward to unlatch it.
Tray
Stabilizer
Latch
6. Slip the old belt off the rollers and slip the new belt on. When the replacement belt has been
properly positioned between the raised edges of its rollers, rotate the tray stabilizer latch to the
latched position.
7. Press down on the top roller to unlock it and allow it to extend.
8. Close the cover. Return the bun compression knobs to their previous settings.
8. Operator Troubleshooting
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
PRO1
PRO1PRO1
PRO1 in LED display.
A. Indicates failure of main platen probe or
associated circuitry.
A. Call FASC.
PRO2
PRO2PRO2
PRO2 in LED display.
B. Indicates failure of holding tray resistor. B. Call FASC.
A. Cover not properly installed.
A. Make sure cover is correctly positioned so
that the cover interlock switch is
depressed.
B. Toaster not plugged in. B. Plug toaster in.
C. Store circuit breaker tripped. C. Reset circuit breaker.
Bun conveyors do not start
when ON/OFF button is
pressed.
D. Failed cover interlock switch, failed high
limit, failed motor, or failed controller.
D. Call FASC.
Toasting is consistently too
dark or too light.
A. Improper setpoint programmed and/or
incorrect compression knob setting.
A. If toasting is too dark, lower the setpoint
and/or compression setting until desired
toasting is achieved.
If toasting is too light, increase setpoint
and/or compression setting until desired
toasting is achieved.