YSCFC SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-7
8. Remove the sensor bulb guard to access the
probe and high-limit (pictured above).
Current production systems have a sensor
bulb clamp that must be removed prior to
removing the probe or high-limit from the
frypot (pictured top right).
9. On the sensor bulb being removed, loosen
and unscrew completely the compression
nut, then the pass-through nut from the
frypot. Carefully remove the sensor bulb
from the frypot, being careful not to damage
the remaining sensor bulb.
10. If removing the high-limit, remove the
screws securing it to the wireway box.
Mark and remove the wiring from the high-
limit housing.
High-limit.
Temperature probe. High-limit.