Additional Errors
Problem Possible Cause Measure
Code No. No No W
No Operation lamp is continuously “ON”
S20
Cooking platform does not
heat enough
U10 Non induction type pan M10
Compare on another
cooking platform and with
an induction type pan
E
U200 1 phase is missing M200
Check mains cable
connection
L
U12 Power board defective M12
Replace power circuit
board
L
U14
CPU-circuit board
defective
M14 Replace CPU-circuit board L
S21
Cooking platform
continuously on
maximum power
U50
Operational control
defective
M50 Check operational control L
U14
CPU-circuit board
defective
M14 Replace CPU-circuit board L
U12
Power circuit board
defective
M12
Replace power circuit
board
L
S22
Empty cooking platform
switches “on“
U220 Pan detection defective M220 Check pan detection L
S23
Little metallic objects are
heated on the cooking
platform
U220 Pan detection defective M220 Check pan detection L
No. Operation lamp  ashes
S24
Cooking platform does not
heat at all
U240
Pan too small (Diameter
less than 12cm, 4.75”)
M240 Use appropriate pan E
U200 1 phase is missing M200
Check connection of
mains cable
L
U220 Pan detection defective M220 Check pan detection L
U241 Short circuit on generator M241
Replace or repair
generator
L
Legend: W = Who should complete “Measure” E = End user L = Supplier