Part # 4526029 (02/22/11)Page 8
SECTION 3 – INITIAL OPERATION
Function control
To check the function controls, the induction generator must
be totally connected.
Display
1. The external lamps must be checked.
2. The operation lamp ashes if a coil is not used (Searching
function).
3. This procedure must be repeated for every coil.
Pan Detection
To check the pan detection, two pans are needed: one with a
diameter of 8cm (3”) and the other with a diameter of 12cm
(4.75”) .Only the pan with a diameter of 12cm (4.75”) should
be detected. A coil should not start operation when it is not
being used.
This procedure must be repeated for every coil.
Power
Place an “induction ready” pan with a diameter of 22-24cm
(8.5”-9.5”) onto the coil. Measure the generator power
at maximum level. This should be at the nominal power
(tolerance +/- 10%). This procedure must be repeated for
every coil.
Fan
Place various pans on the coils and start the generator on
the highest level. After a few minutes the fan should start.
The fan is controlled by the temperature and starts when the
heat sink temperature is about 50ºC/122ºF.