Garland 7000 Cooktop User Manual


 
Part # 4526029 (02/22/11)Page 14
Adjustments
This induction unit has been correctly adjusted by the
manufacturer. Any adjustments have to be made with
caution. Please pay attention to the following points:
1. Note the original position of the poti’s: remember the
number of turns you make.
2. Errors can occur after wrong adjustments
3. Only small corrections can be made with adjustments
Generator Type
The generator type is adjusted in the binary code with the
DIP-switches 5 to 8 on the CPU-circuit board
Switch Position
DIP-Switch for
generator type
8765
0
1 ON
2ON
3ONON
4ON
5ONON
6ONON
7 ONONON
8ON
9ON ON
10 ON ON
11 ON ON ON
12 ON ON
13 ON ON ON
14 ON ON ON
15 ON ON ON ON
Switch Power
Summary: software and generator type
The following list shows the number of types of the various
generators.
Please note the positions of the power switches from the
above table.
Type
DIP
Switch setting
MO/DU 7000, 208V 6 and 8 on
MO/DU 7000, 400V 5 and 8 on
Pan detection
The potentiometer on the recti er circuit board is used to
adjust the pan detection:
Turn clockwise: acceptance of smaller pans
Turn counterclockwise: only bigger pans are accepted
Power
Only one potentiometer per  eld is available on the power
circuit board to adjust the power:
Turn clockwise: less power
Turn counterclockwise: more power
Repair by Garland
If the generator has to be repaired by the manufacturer,
please enclose an exact description of the error. If possible,
use the original package for the return. If it isn’t available,
do not use porous material for wrapping (like styropor). This
could enter the unit and the electronic parts and is di cult
to remove.