Garland BH/IN 2500 Cooktop User Manual


 
Part # 4520898 (03/31/11) Page 23
TROUBLESHOOTING continued
Malfunction With Error Code
Number of Flashing
Signals (Code)
Possible Cause Action To Take By Operator Or Operating
Personnel
E03
- . . . - . . .
Overheated heat sink Let unit cool down
Check air lter and air ow
Air-cooling system obstructed Verify that air inlet and air outlet are not
obstructed with objects
Clean air lter
E04
- . . . . - . . . .
Overheated cooking zone Let unit cool down
Check air lter and air ow
E06
- . . . . . . - . . . . . .
Overheated electronic Let unit cool down
Check air lter and air ow
Ambient temperature too high (the cooling
system is not able to keep the cooker in normal
operating conditions )
Verify that no hot air is sucked in by the fan.
Reduce the ambient temperature. The air inlet
temperature must be lower than 104°F/40°C
E07
- . . . . . . . - . . . . . . .
Empty cooking sensing element activated Reset empty cooking protection by switching
the unit o
E08
- . . . . . . . . - . . . . . . . .
Ambient temperature beyond operating range Make sure that the operating conditions
(especially the ambient temperature) are kept
Error on sensing element Contact service agent
Order of error message: The indicator lamp lights up for an interval of 0.6 sec. The number of the following short ashes has to be
counted and informs about the kind of error corresponding to the above mentioned code system.
The code will repeat until the error is cancelled.
The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At heat
temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal operating
conditions. The cooker runs in a non continuous mode. This mode can be heard.