Part # 1382698 (02/26/08)Page 4
SPECIFICATIONS
INTRODUCTION
U.S. Range manufactures the “Regal” Hot Plate in widths
ranging from two feet to ve feet, and either one or two
burners deep, to be used as free-standing counter units.
All units are shipped completely assembled, with the
pressure regulator and adjustable legs packed on the
drip pan. The burners are tied to their hangers to prevent
vibration damage. All units are inspected at the factory prior
to shipment.
Like any ne, precision built piece of equipment, your
appliance should be given regular care and maintenance.
Periodic inspections by your dealer or a qualied service
agency are recommended.
Uncrating
After uncrating, immediately check the equipment for visible
signs of shipping damage.
If such damage has occurred, do not refuse shipment, but
contact the shipper and le the appropriate freight claims.
Rating Plate
The rating plate is attached to the hot plate’s end frame. It
can be viewed by tilting the unit and looking underneath. A
ashlight may be necessary.
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prex and sux
letters and numbers) and the warranty serial number. The
rating plate axed to the unit contains this information.
Other information on this plate is the BTU/hr input to the
burners, outlet gas pressure in inches WC, and whether
oriced for natural or propane gas.
WARNING All U.S. Range Hot Plates must be connected only
to the type of gas identied on the rating plate! Installation
must be in accordance with ANSI 283.11 (latest edition) of
the American national Standards Institute, Inc.
MODEL NUMBER
NATURAL GAS LP GAS
Orice Size Total Input Orice Size Input
RHPA-1112A 46 20,000 BTU 56 17,500 BTU
RHPA-212A & RHPR-12 46 40,000 BTU 56 35,000 BTU
RHPA-224A 46 40,000 BTU 56 35,000 BTU
RHPA-336A 46 60,000 BTU 56 52,500 BTU
RHPA-424A &RHPR-24 46 80,000 BTU 56 70,000 BTU
RHPA-448A 46 80,000 BTU 56 70,000 BTU
RHPA-636A & RHPR-36 46 120,000 BTU 56 105,000BTU
RHPA-848A & RHPR-48 46 160,000 BTU 56 140,000 BTU
Operating pressure is 5” WC for Natural Gas and 10” WC for LP Gas.