Garland SU680 Ventilation Hood User Manual


 
Part # P153 Rev 1 (02/21/08)Page 10
NOTE: When mounting a salamander over an existing range
in the eld, an independent fussed connection must be
made though the knock out plate provided in the main back
of the salamander.
Assembly of Backguard/High Shelf
The back guard or high shelf will have been shipped
separately. To install, put the backguard/high self on the rear
of the range, slipping the uprights into the opening on each
burner box side. Fasten the upright to the burner box side
with four hex fasteners provided.
Code Requirements
The Garland S/SS680 series complies with the standards CSA
C22.2 no.109 – latest edition, the UL197 – latest edition and
the NSF#4 – latest edition. The installation and connection
of this appliance must comply with current codes. In Canada
– The Canadian Electrical Code Part 1 and in the USA – The
National Electrical Code.
The Garland SU680 series complies with the essential
requirements of the Directives 73/23/EEC, 89/336/EEC,
89/392/EEC, 93/68/EEC and the standards, EN60335,
IEC801.2, IEC801.3, IEC801.4, IEC801.5, IEC801.6 and
IEC801.11.
Electrical Supply
Before attempting the electrical connection, the rating plate
should be checked to ensure that the equipment’s electrical
characteristics and supply electrical characteristics agree. On
ranges and salamanders the supply entrance is located at the
rear or alternatively on the main bottom. The supply terminal
block is accessible from the front. The electrical supply must
be adequate for the voltage, phase, and current marked on
the rating plate.
INSTALLATION Continued
NOTE: A means of disconnection from the supply having
a contact separation of at least 3 mm in all poles must be
incorporated in the xed wiring.
This equipment is intended to be installed with xed
permanent wiring.
WARNING: This appliance must be grounded.
Single And Three Phase Connection
Unless otherwise noted, all ranges are shipped from the
factory for three phase connection. Salamanders are shipped
from the factory for single phase connection. A wiring
diagram is attached to the rear of each appliance. Visually
check all electrical connections. The range is wired at the
factory as specied on the order. If it is necessary to change
the phasing refer to the wiring diagram.
Commissioning
Ensure all circuit breakers located in the lower compartment
are set to the ON (1) position
1. Ensure that all controls are in the OFF position and turn
on the main electrical supply.
2. Operate each section of the range or salamander in
accordance with the instructions given in the Operating
Instructions.
3. Check that the product functions correctly and that the
voltage supply to the unit does not drop more than 5%
when all sections are operated simultaneously.