GE JGP989 Cooktop User Manual


 
INSTALLING THE BLOWER TO
THE PLENUM
Orient the blower discharge opening to
match the ductwork in Steps 5 and 6. Slide
the four threaded studs on the side of the
blower housing into the four holes on the
side of the plenum.
NOTE: See Step 13 for installing the transition
duct to the blower. It may be easier to install
the transition duct to the blower before
installing the blower to the plenum.
From the vent opening in the top of the
cooktop, fasten the blower assembly securely
to the plenum with four (4) nuts.
INSTALLING THE HOLD-DOWN
RETAINERS
NOTE: Check for glass flatness in Step 9
before installing hold-down retainers.
Secure cooktop to the counter using the
hold-down retainers and thumb screws
shipped with the unit (one on each side,
or one on front and one on back).
Hold-down retainer
Use slot position
appropriate for
countertop thickness
Hold-
down
retainer
Thumb screw
Countertop
10
12
INSTALLING THE BLOWER
PLENUM TO THE COOKTOP
Slide the plenum, with the blower opening on
the left, into the opening in the bottom of the
cooktop. Push up on the plenum until the
stops on the plenum contact the bottom of
the cooktop, and snap the plenum into place.
(You may have to move the plenum back and
forth to work it into place.)
Secure the plenum to the bottom of the
cooktop, on each side, using the four (4)
screws provided. Further secure the plenum
to the cooktop, from the top side, using the
two screws (2) provided.
11
4 Nuts
(7/16
socket
required)
Installation Instructions
INSTALLING THE COOKTOP
26