GE JGBP33WES Range User Manual


 
CONVERTING SURFACE BURNERS ON
MODELS EQUIPPED WITH SEALED BURNERS (See
Step 4 if range is equipped with dual burners.)
Burnercap~
1. Remove grates, burner caps and burner heads.
2. Remove burner bases by unscrewing the 3
small screws in each base.
~
burner
straight out.
DO NOT
disconnect the wires from the burner
bases unless the
cooktop
needs to be raised.
3. Remove the brass orifice spud under each
burner base by unscrewing spud from fitting with
7mm
or 5/16” wrench (depending on the size of
your spuds).
Apply a 3/4” wrench to
tie
hex
on the gas inlet tube as a back-up when
removing spud to prevent
the
aluminum
tube
horn
twisting.
4.
Install orifice spuds
accordin
to one of the
d
following diagrams (see
or
B ),
for
LP
gas or natural gas, depending on which you are
converting to.
Orifice Spuds for Converting to LPGas:
LP
orifice spuds are in a small plastic bag packed
with this Use and Care book.
LP
or~lce
spuds
have a 2-digit number and the Letter “L” on
one side. Each orifice spud will also have 1 or 2
grooves on one side, denoting the location on
the range where it is to be installed.
Orifice Spuds for
Convetiingto
Natural Gas:
Natural gas orifice spuds have a 3-digit number
on one side. Each
or~lce
spud will also have 1, 2
or 3 grooves on one side, denoting the location
on the range where it is to be installed.
(([]ntinued
next page)
43