GE PVWT936 Ventilation Hood User Manual


 
Installation Instructions
10
OPTIONAL ACCESSORIES
1 Ft = 0.3 m
1” = 2.5 cm
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Additional Materials:
120V 60Hz. 15 or 20 Amp, 2 wire with ground.
Properly grounded branch circuit.
Strain relief for junction box.
7” round metal duct or 3¼” x 12” rectangular duct, length
to suit installation.
Duct tape
¼” pivoting hex socket
Pencil and
tape measure
Spirit level
Phillips and
Flat blade screwdrivers
Electric drill with
1
/8” and
3
/8” bits
cUL Listed Wire nuts
Hammer
Safety glasses
Metal snips
Flashlight
Pliers
Wire Cutter/Stripper
Saber saw or Key Hole Saw
Ladder
Allen Wrench
Kit 01235 Model PVIG940
Chimney + Structure 84 - 121.5 cm
(Venting)
Kit 01237 Model PVWG936
Chimney 51.5 cm
Kit 01238 Model PVWT936
Chimney 70 - 140 cm (Venting)
Kit 01239 Models PVWS930/936
Chimney 92.5 - 132 cm (Venting)
Ductless Recirculating Kit
Kit 01378 Models PVWS930/936, PVWT936
Carbon Filter + Filtrating Deflector:
Changes Hood from Venting to
Filtrating
Kit 01379 Model PVWIG940
Carbon Filter + Filtrating Deflector +
RUA: Changes Hood from Venting to
Filtrating
PARTS PROVIDED
Hood canopy with internal blower, grease filters and
lights already installed
Duct covers
Duct Cover support bracket
Transition (may be already installed)
Hardware Packet:
Note: the hardware packet contains several fittings material.
For models PVWS930, PVWS936 and PVWT936, consider
what is listed below ONLY:
Hook with leveling screws x 2
Template
Use, Care and Installation Guide
10 x 60 drywall anchors x 2 (To attach duct cover
support bracket)
6 x 80 screws x 8 + washers x 8 (2 To attach duct cover
support bracket + 6 to attach the hood canopy)
3,5 x 9,5 screws x 6 (2 to attach the transition + 4 to
attach the duct cover)
MODELS PVWS930, PVWS936 AND PVWT936