CONVERT THE SURFACE BURNERS
1. Remove grates and burner caps.
2. Using the 7 mm nut driver,
remove and replace the brass
orifice spud inside each burner
chimney as follows:
• Replace the large orifices with
the spuds that are stamped 104.
• Replace the small orifices with
the spuds that are stamped 82.
NOTE: There will be one
extra orifice spud when
converting a four burner cooktop.
3
CONVERTING TO LP GAS
or Converting Back to Natural Gas from LP
CONVERT THE SURFACE KNOBS
1. Remove the knobs and
lift off the microswitch
operating cams from
the valve shafts.
2. Fully screw down the
brass low flame
adjustment screws into
the valve bodies with a
clockwise rotation.
3. Replace the knobs
and cams.
2
This cooktop leaves the factory set for use with
natural gas. If you convert to LP gas, keep these
instructions and orifices in case you want to convert
back to natural gas.
The conversion should be done by a qualified
technician or installer.
PARTS:
Check the contents of the kit, which should
contain the following:
• 2 Orifice—Large size—104-WB28K0093
• 3 Orifice—Regular size—82-WB28K0094
• 1 Maxitrol LP adapter—WB01K055
• 1 Tie-on card/label for regulator
If you do not have all the above listed components,
or if you are in any doubt, please contact the nearest
GE Service and Parts Center.
USE ONLY APPROVED PIPE DOPE RESISTANT
TO LP GAS.
Total input rating after conversion:
• 5 burner cooktop 40,000 Btu/hr.
• 4 burner cooktop 34,000 Btu/hr.
TOOLS REQUIRED:
Adjustable wrench
Nut drivers: 9/32or 7 mm
PREPARE COOKTOP FOR CONVERSION
(1) Turn off gas supply at the wall.
(2) Turn off the electrical power to the cooktop.
1
(continued next page)
Top grate
Valve
Shaft
Burner Cap
Cam