GE Monogram ZXR758 Ventilation Hood User Manual


 
Installation Preparation
4
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible. Wiring should enter at least 4"
above the bracket on the right side.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING: The improper connection
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
TOOLS AND MATERIALS
REQUIRED
(NOT SUPPLIED)
Tape measure
Knife
Spirit level
Wire cutter/stripper
Wire nuts
Electric drill and
appropriate bits
Phillips and flat blade
screwdrivers
Hammer
Pliers
Center punch
10 mm Hex wrench/socket
Safety glasses
Duct tape
Gloves to protect against sharp
edges
120V 60Hz. 15 or 20 Amp, 2 wire
with ground. Properly grounded
branch circuit.
Strain relief for junction cover.
6" round duct, length to suit
installation.
DUCT COVER ACCESSORIES
A duct cover accessory is required for recirculating
operation. Use this chart to determine which
accessory is required for your ceiling height.
A
B
11-7/8"
9-1/4"
Hood and
Accessory
ZXR758C
ZXR7510C
ZV750SY Duct Cover Dimensions
A
18-7/8
18-7/8
B
22-13/16
34-5/8
ZV750SY Installation Heights
* Based on 36 countertop height.
Actual
Ceiling
Height
7 11
8 0
8 1
8 2
8 3
8 4
8 5
8 6
8 7
8 8
8 9
8 10
8 11
9 0
9 1
9 2
9 3
9 4
9 5
9 6
9 7
9 8
9 9
9 10
9 11
10 0
* Possible Hood
Installation Height
24-1/2
25-1/2
25-1/2 to 26-1/2
25-1/2 to 27-1/2
25-1/2 to 28-1/2
25-1/2 to 29-1/2
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
25-1/2 to 30
Recirculating
Accessory
ACCESSORY ZXR7510C
ACCESSORY ZXR758C