Grindmaster 20H Coffeemaker User Manual


 
Grind’n Brew® Coffee Systems Page 15
ƽ CAUTION: Unplug power cord from outlet before cleaning or servicing the unit.
Troubleshooting Guide
The following procedures must be performed by a qualified service technician.
Problem Possible Cause Remedy
Weak coffee Not enough coffee used
Grind is too coarse
Water not hot enough
Too much water used (half brews)
Coffee bed has dry areas
Set to portion more coffee.
Readjust grind to a finer grind.
Check spray temp, should be
greater than 185°F.
Adjust brew time at the controller.
Spray deflector broken or missing.
Replace.
Strong coffee Too much coffee used Readjust coffee portion.
Bitter coffee Grind is too fine Coarsen grind setting.
Grounds in coffee Paper filter collapsed during
brewing
Use proper filter.
Brew basket overflowed Too much coffee
Coffee ground too finely
Double batching
Use no more than 3 1/2 oz. of coffee.
Coarsen grind.
You must dump old coffee and use
fresh new filter for each brew.
Unpleasant taste Water tank or brew basket needs
cleaning
Clean, sanitize (de-lime).
Refer to Regular Maintenance
section.
Brewer will not brew Basket has not been changed Remove basket, replace filter,
reinstall.
Grinder will not start when start
button is pushed
Main power switch turned off
No power to outlet
Basket out
Circuit breaker has tripped
Basket has not been changed
Turn main power switch, on located
on back of unit (left side from front) on.
Check outlet with lamp or radio to
verify outlet has power.
Ensure basket is in position.
Reset circuit breaker (located on
back of unit) by pushing the reset
button in until you hear a click.
Remove basket, replace filter,
reinstall.
Grinder runs or hums but no
coffee is dispensed
Shear disc is broken
Obstruction in opening of auger
assembly (on dual bean units)
Obstruction in opening to grinding
chamber
Slide valve is bending
Blown fuse on controller board
(Dual bean only)
Replace shear disc. See Shear
Disc Replacement section.
Remove hopper and clear
obstruction.
Remove hopper and clean
obstruction.
Check for free operation of slide valve.
Adjust solenoid mount or slide valve
mount as required. Make sure white
slide valve gasket is not touching
moving parts.
Check for blown fuse and replace
with 5 Amp fuse.
Quantity of coffee dispensed
each throw is not the same
Defective timer in controller
Slide valve is binding
Check the length of time grinder
runs with watch.
• Remove upper assembly and clean
obstruction.
Check for free operation of slide
valve. Adjust solenoid mount or
slide valve mount as required.
Make sure white slide valve gasket
is not touching moving parts.