Grindmaster P200E Coffeemaker User Manual


 
Page 10
Troubleshooting: Filling, Heating, and Brewing (con’t.)
Brewing Problems
The brewing system consists of the following components:
Start and Stop switches, located on the front control panel.
Brew Timer, located in the top control section under the top cover.
Brew volume too
large or too small.
Timer out of ad-
justment.
Pressure not ad-
equate at brewer.
Spray head clogged.
Timer faulty.
Compare timer setting
to factory setting
chart.
Check water flow before
removing strainer.
Visual
Check if brew time
matches timer setting
and if timer can be
adjusted.
Adjust timer.
Clean or rinse strainer at fill valve.
Clean all holes.
Replace timer.
Problem Possible Cause Service Check Remedy
Brew volume erratic.
(there is always some
small variation from
batch to batch)
Timer faulty.
Pressure fluctuations
at brewer.
Measure brew time for
inconsistencies.
Check pressure at
brewer inlet.
If time is different from batch to
batch, replace timer.
Plumb water line so its pressure is
not influenced by other appliances.
Brew will not
start.
Tripped circuit
breaker.
Brew valve faulty.
Stop switch faulty.
Start switch faulty.
Timer faulty.
Check to see if circuit
breaker tripped or
popped out.
Check 120V across
brew valve.
Check for continuity
across stop switch
when not pressed.
Check 120V between
S.S. and N on timer
when start is pressed.
Check 120V between H
and N on timer. If OK,
check for 120V between
BREW and N on timer
after pressing start.
Reset or replace breaker.
If 120V is across brew valve, but brew
valve doesn't open, replace coil or valve.
If no continuity, replace switch.
If start switch does not provide 120V
start signal, replace switch.
If no 120V BREW output from timer,
replace timer.
Spray head will not
stop dripping water.
(spray heads normally
drip slightly after
brew)
Boiling tank.
Limed up Fill valve.
If drip is from right side,
check for water from
overflow outlet at top of
tank.
Visual check of valve.
Turn down thermostat. If that doesn't
cure, check for faulty thermostat or
heater relay.
Clean valve. Valve seal or entire
valve may need replacement.
P200/RAPS200 Brewers