Adjustments
WARNING: ELECTRIC SHOCK HAZARD
DANGEROUS ELECTRIC VOLTAGES ARE PRESENT NEAR ADJUSTABLE
COMPONENTS. ALL ADJUSTMENTS SHOULD BE PERFORMED BY
QUALIFIED SERVICE PERSONNEL ONLY.
All adjustable components are located under the top cover. To access these parts:
1) Unplug the brewer.
2) Remove the screw fastening the top cover. Remove the top cover.
Brew Volume Adjustment
The brew volume of the P200/RAPS200 brewer is controlled by its timer. The batch size is directly
proportional to the timer setting. The timer adjustment is located under the top cover.
There will always be a small variation (+/- 5%) in level from batch to batch.
Before making the timer adjustment, do the following:
1) Brew a batch of water to determine where the level falls. Using a stop watch, determine
the current brew time. Measure the volume of water.
2) To determine the desired time setting, use the following formula:
desired brew volume
desired brew time = _________________ X current brew time
current brew volume
Timer Adjustment
Two Batch Timer with Knob Adjustment, See Figure A:
1) This timer is adjustable from 15 seconds to 5 minutes. Locate the
adjustment knobs under the top cover.
2) Set this timer by adjusting the knob. The batch selector switch
picks the adjustment potentiometer which the timer will see.
P200/RAPS200 Brewers