English
32
Problem Cause Solution
Automatic icemaker
The
icemaker
has stopped
making ice.
• The ice cube height sensor
arm has detected a full
tray condition.
• The water supply valve is
closed.
• The freezer section is not
cold enough.
• The water source saddle
valve is somehow blocked.
• To make more ice cubes you
may need to distribute your ice
to the center drawer right side
(or lower drawer) to increase
ice cube harvest volume.
• Turn on the water supply valve.
• Adjust the setting in the freezer
to a colder setting and allow it
to balance within 24 hours.
• Check the water supply
saddles valve for obstruction
and replace it if damaged.
The ice
making
capacity is
low.
• The freezer drawer area is
not cold enough.
• The water supply valve
does not have enough
pressure or does not open
all the way.
• The icemaker sensor arm
is restricted or out of
position.
• Set the freezer drawer to a
colder setting.
• Make sure the water pressure
is between 25-121 psi and
add water booster if too low.
• Make sure the water valve
supply is open all the way.
• Make sure the water filter is
distributing enough water and
is not clogged.
• Make sure the drawer gaskets
are sealing and kept clean
from dirt and debris.
The
icemaker
runs
continuously.
• The icemaker level sensor
is stuck in the down
position.
• Check the movement of the
icemaker sensor arm so it rests
in the “up” position.
• Make sure no frozen packs or
objects are obstructing the
icemaker sensor arm.