Heartland Bakeware 9200/7200 Range User Manual


 
9
Installation through an
attic to an outside wall
If the vent elbows are embed-
ded in the wall, the range may
be positioned as shown in
Page 9, Figure 5. Continue
the ducting through the ceiling
into the attic. Terminate duct
either on an outside wall just
below the sofit using a vent
hood or through the roof with
a roof cap. Seal with caulking
around and under cap or
hood.
Complete your installation by
following directions under
Ventless Installation.
Installation of Ducting
Installation through an outside wall
Remove air deflector (used for ventless operation only). Cut appropriate-sized hole through the wall directly behind the
range hood outlet (see Figure 5, page 9), making sure no wall studs are cut. Push range into position. From outside of
the house, measure distance from the siding to the range outlet. Cut duct pipe that length, plus 1" (25mm) for overlap
into outlet. Attach vent hood to pipe. Caulk the back of vent hood and around pipe where it goes through wall and into
range hood outlet so caulking seals against outside siding.
Complete installation by following directions under Ventless Installation.
14”
36 cm
28”
72 cm
29-1/2”
75 cm
14”
36 cm
29-1/2”
75 cm
28”
72 cm
56”
142 cm
66-1/4”
168 cm
62-3/8”
159 cm
29-3/4”
76 cm
36-1/8”
92 cm
13-3/4”
35 cm
RangeHoodOutlet
3-1/4” x 10”
8 cm x 25 cm
3-3/4”
10 cm
34”
86 cm
Gas Inlet-1/2” NPT
Power
Cord
Exhaust
Hood
(female)
Receptacle
RangeHoodOutlet
3-1/4” x 10”
8 cm x 25 cm
66-1/4”
169 cm
56”
142 cm
36-1/8”
92 cm
Gas Inlet-1/2” NPT
Power
Cord
Exhaust
Hood
(female)
Receptacle
20”
51 cm
4-3/4”
12 cm
30”
76 cm
39-3/4”
101 cm
47-1/2”
122 cm
Figure 6
Model 7200
Figure 7
Model 9200