Henny Penny 680 Fryer User Manual


 
The gas control valve is a dual controller, in which one side
of the control valve controls one burner and the other side of
the control valve controls the other burner. If one burner shuts
down, both burners will shut down. The control valve is turned
on or off, it has no pilot position, because the burner does not
require a pilot light.
To avoid injury or property damage, before starting
this procedure, move the Power/Pump switch to the
“OFF” position. Disconnect the main circuit breaker
at the circuit breaker box, or unplug the service cord
at the receptacle. Turn off the main gas supply to the
cooker and disconnect and cap the supply line to fryer,
or possible explosion could result.
A voltage check at the control valve must be taken four
(4) seconds after the Power/Pump switch is turned to
Power position.
1. Turn gas cock knob to the “OFF” position.
2. Pull gas cock knob from control valve.
3. Remove cover from control valve.
4. Using an allen wrench, remove shaft extension from
control valve.
5. Remove left side panel.
6. Unscrew nut from outlet line under the control valve.
7. Measure air slide adjustment from manifold to end of air
slide and slide air slide all the way in.
8. Loosen nut from inlet line going to control valve.
9. Remove wires from control valve.
10. Remove the two screws and nuts from bracket and remove
bracket.