Henny Penny HCW-5 Food Warmer User Manual


 
Model HCS-2/HCW-3/HCW-5/HCW-8
2-6. ELECTRICAL CONNECTION The electrical power can be connected from the bottom or from the
(Continued) operator’s side. There is a 1-3/32 inch diameter hole for either
connection. Again, we recommend the bottom connection as this
will give a cleaner appearance to the unit. Please observe the
electrical connection information on the data plate located on the
side panel of the control end.
Voltage potential of L1 and L2 to ground cannot exceed
125 volts, or damage to the unit could result.
2-7. ELECTRIC DATA TABLE Model Volts Phase Watts Amps
HCW-2 120/230 1 760 4.7
HCW-2 120/208 1 760 4.9
HCS-2 230 1 2852 12.4
HCW-3 120/230 3 3400 10.7
HCW-3 120/230 1 3400 16.3
HCW-3 120/208 3 3400 11.5
HCW-3 120/208 1 3400 17.6
HCW-3 400 3 3400 5.0
HCW-5 120/230 3 4160 12.2
HCW-5 120/230 1 4160 18.0
HCW-5 120/208 3 4160 13.1
HCW-5 120/208 1 4160 19.5
HCW-5 400 3 4160 6.0
HCW-8 120/208 3 8080 26.0
HCW-8 120/208 1 8080 40.0
HCW-8 120/230 3 8080 24.0
HCW-8 120/230 1 8080 35.1
HCW-8 400 3 8080 11.7
HCS-5 120/208 3 8080 22.6
HCS-5 120/208 1 8080 40.0
HCS-5 120/230 3 8080 19.8
HCS-5 120/230 1 8080 35.1
HCS-5 400 3 6680 9.7
2-8. WATER SUPPLY The automatic water system has a 1/4 inch compression fitting for
CONNECTION copper tubing. Hot water would be preferred. We recommend
using the automatic water system as this will allow the unit to
maintain a more even water temperature and help ensure that the
unit never runs dry of water.
A straight-through bulkhead fitting is furnished with the unit for
1/4 inch copper tubing to protect the water line where it passes
through the sheet metal.
Reinstall the end panel.
1006 2-5