Henny Penny LCG Fryer User Manual


 
+STEP56
PROG
START
ACTIV
CLEANJET
24:00
56
Unit must be on, WITHOUT CleanJet arm(s) attached, and no mode selected.
Press TEMPERATURE and TIMER keys simultaneously for about 10 seconds
or until the TIMER display reads 24:00 or AM:PM.
Press TEMP key three times. Either +STEP 0, STANDARD or
+STEP56 will appear.
Use Central Dial to select desired step.
Press PROG/START. All displays go out indicating program was copied and
saved to CleanJet location.
Turn unit off and follow the procedures above beginning with step 2.
7. Press PROG/START to begin cleaning cycle. ACTIV and CLEANJET
shows in the display. Remaining cycle time shows in the TIMER display.
See charts on page 57 for duration of each cleaning program.
8. Unit shuts off automatically when cycle is complete.
Tips
To stop the cycle for any reason, it is necessary to switch the unit off.
If the unit is turned off for any reason during cleaning cycle (or if power to the
unit is interrupted,) cycle will be suspended. When the unit is switched back
on (or when power is restored,) the cleaning cycle will NOT continue. Instead,
ABORT is displayed. Press PROG/START to run through a short rinsing
cycle to clear the cabinet of any remaining detergent and/or loose debris.
Operator may now repeat entire cleaning cycle.
Hand cleaning accessibility
The hinged racks can be removed for cleaning by lifting up on the racks,
swiveling them inward, and lifting them off their mountings.
If using the mobile oven rack system, roll the rack out of the unit and remove
the guide frame from the bottom of the unit by lifting it upward out of its
mountings.
The air baffle, covering the left side of the interior cabinet, provides even airflow and
protects operator from heating elements and fan. To open the baffle for cleaning:
1. Turn unit off and disconnect electrical power to unit.
2. Swivel left hinged rack inward. (If using mobile oven rack, remove rack and
guide frame.)
3. Using a flat-head screwdriver or a coin, turn the two quick fastening locks
one-quarter turn counterclockwise. Baffle will swing open for cleaning.
NOTEfloor units have 2 air baffles that open in this manner.
Safety protection (gloves, goggles, etc.) is required when working with cleaning
products. Please refer to cleaning product guidelines before use.
CLEANING