Problem Cause Correction
HEATING OF SHORTENING SECTION
Gas valve knob turned to the OFF Make sure the gas valve knob is
position turned to the ON position.
Blown fuse or tripped Reset breaker or replace fuse
circuit breaker at supply
box or control panel
Blown fuse in PC board Replace glass fuse in board
Faulty POWER/PUMP switch Check POWER/PUMP switch
per POWER/PUMP Switch Section
Faulty cord and plug Check cord and plug and
power at wall receptacle
Faulty drain switch Check drain switch per
Drain Switch Section
Faulty PC board Remove and replace control
panel
Faulty high limit control switch Check high limit control
switch per High Temperature Limit
Section
Drain valve open Close drain valve
Possible faulty gas control With power removed from
valve fryer, check across electrical
leads of gas valve
with multimeter, and gas
valve on ON position
Possible faulty temperature probe Replace temperature probe
Bad spark ignitor Replace spark ignitor
Low air pressure Clean or replace blower
Replace air pressure switch
Faulty ignitor module Replace ignitor module
Spark ignitor or flame sensor out of The spark ignitor needs to be 1/8 in.
adjustment from the pilot hood, and the
flame sensor, 1/4 in
Shortening will not heat
1003 1-7