1-4. ERROR CODES (Continued)
CE Only - Along with the error codes from the preceeding
pages, CE units have the following self-diagnostic error codes:
DISPLAY CAUSE PANEL BOARD CORRECTION
“E10” High limit Reset the high limit by manually pushing up on the red reset
button; if the high limit does not reset, the high limit must be
replaced per High Limit Temperature Control Section
“E15” Drain switch Close the drain, using the drain valve handle; if display still
shows “E-15”, check the drain microswitch per Drain
Microswitch Section
“E-20 A” Air pressure Press the Timer button to try the ignition process again,
switch failure and if “E-20 A” persists, call Henny Penny’s Service
(stuck closed) Department
“E-20 B” Draft fan or Press the timer button to try the ignition process again,
air pressure and if “E-20 B” persists, call Henny Penny’s Service Depart-
switch failure ment; number of failures can be seen in Review Usage Section
(stuck open) of Operator’s Manual, then press “Exit Cool”
“E-20 C” Left gas module Press the timer button to try the ignition process again, and
failure if “E-20 C” persists, call Henny Penny’s Service Department
“E-20 D” Right module Press the timer button to try the ignition process again, and if
failure “E-20 D”, persists, call Henny Penny’s Service Department
“E-20 E” Both modules Press the timer button to try the ignition process again, and if
failure “E-20 E”, persists, call Henny Penny’s Service Department
“E-20 F” Left module- Press the Timer button to try the ignition process again, and if
no flame sense “E-20 F”, persists, call Henny Penny’s Service Department
“E-20 G” Right module- Press the timer button to try the ignition process again, and if
no flame sense “E-20 G”, persists, call Henny Penny’s Service Department
“E-20 H” Both modules- Press the timer button to try the ignition process again, and if
no flame sense “E-20 H”, persists, call Henny Penny’s Service Department