2-9. GAS CONTROL VALVE The gas control valve sends regulated gas to the burners when the
controller calls for heat. The control valve can be turned on
or off. In the on position, and the power switch on, a spark ignitor
lights a standing pilot, and when the control calls for heat, the valve
is opened and the burners are ignited.
Safety Precautions
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING GAS CONTROL
VALVE DO THE FOLLOWING:
MOVE THE POWER SWITCH TO THE OFF
POSITION.
DISCONNECT THE MAIN CIRCUIT BREAKER AT
THE WALL, OR UNPLUG THE POWER CORD.
TURN OFF THE MAIN GAS SUPPLY TO THE
FRYER AND DISCONNECT AND CAP THE SUPPLY
LINE TO FRYER, OR POSSIBLE.
Replacement
A voltage check at the gas control valve must be taken four (4)
seconds after the POWER switch is turned to the ON position.
1. Turn gas knob to the OFF position.
2. Remove cover from control valve.
3. Remove the wires from the control valve.
2-9 1003