Hobart D Series Refrigerator User Manual


 
9
Program Review
During normal Operation Mode, with the SET CLOCK light blinking rapidly . . .
Press the SET button until the SET CLOCK, PROGRAM and
DEFROST ON lights are lit; then release the SET button and all
three lights go off for two seconds. After that, all three lights begin
to blink. The number of blinks of a light corresponds to the
programmed value for that light (Fig. 15). A three second pause
follows the last blink before the cycle repeats. The Review Mode's
sequence of blinking lights repeats ten times to give you plenty of
chances to count the number of blinks for each light. Review Mode
can be stopped at any time by pressing the SET button for 3
seconds; when the SET button is released, normal Operation
Mode returns with the SET CLOCK light blinking rapidly.
The SET CLOCK light blinks from 1 to 12 times to indicate the
TIME CLOCK HOUR. If the final blink for the hour count
remains on for two seconds, it indicates PM; if the final blink
for the hour count is a normal blink, it indicates AM.
While the SET CLOCK light is blinking the HOUR, the PROGRAM
light blinks from 0 to 11 times to indicate the TIME CLOCK
MINUTES to the nearest 5 minutes after the hour: 0 blinks =
0 minutes, 1 blink = 5 minutes, 2 blinks = 10 minutes, . . .
11 blinks = 55 minutes.
While the SET CLOCK light is blinking the HOUR and the
PROGRAM light is blinking the MINUTES, the DEFROST ON
light blinks from 0 to 11 times to indicate the DEFROST
DURATION setting to the nearest 5 minutes: 0 blinks = 0
minutes, 1 blink = 5 minutes, 2 blinks = 10 minutes, . . .
11 blinks = 55 minutes.
After the ten blinking sequences are done or after Review Mode
has been stopped, normal Operation Mode returns with the
SET CLOCK light blinking rapidly.
Initiating a Manual Defrost
During normal Operation Mode, with the SET CLOCK light blinking rapidly . . .
Press the MANUAL DEFROST button for about 3 seconds until
the DEFROST ON light comes on. The Defrost Cycle is started
and continues for the amount of time programmed for DEFROST
DURATION (page 7).
Cancelling a Defrost Cycle
While a Defrost Cycle is in progress, the DEFROST ON light is lit.
A Defrost Cycle that is in progress can be terminated by pressing
the MANUAL DEFROST button for 3 seconds. The DEFROST
ON light goes off.
The normal DEFROST SCHEDULE continues to operate as
programmed.
Fig. 15
# Blinks (times 5) =
DEFROST DURATION
# Blinks = HH
# Blinks (times 5) = MM
Current Clock Time = HH:MM