(7.5, 9 Load / 8 Center / 7.5, 9, 11 Unload)
Machine Ratings (Mechanical)
Conveyor Speed — Feet per minute 4.0 - 8.5
Dishes per Hour 14,316
Motor — Horsepower ASR Soil -
1
4; ASR Wash -
1
3; Pre-Wash - 3
1
2; Wash - 5; Rinse - 5;
Dual Rinse -
1
6; Final Rinse -
1
2; Conveyor -
1
3; Blower Dryer - (2) 2
Tank Capacity — Gallons ASR - 7.2; Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 7.2
Rate of Final Rinse — Gallons per minute
(Pumped rinse) .97
Final Rinse Consumption — Gallons per hour
(Pumped rinse) 58
Exhaust Requirements — Cubic feet per minute
(if supplemental ventilation is required to handle
machine’s latent and sensible heat)
750
(at standard air conditions)
Latent/Sensible Heat — BTU per hour Electric - Latent: 108,300 / Sensible: 46,400
Steam - Latent: 132,100 / Sensible: 56,600
Electric Heat Requirements
Tank Heat - Kilowatt (Regulated)
Electric Booster - Kilowatt
Disconnect switches are recommended for each power circuit connected
to dishwasher. These disconnect switches are NOT furnished by Hobart
and should be installed by the electrical contractor at the time of installation.
Circuit breakers optional at extra cost.
Total tank heat - 43KW (Wash, Rinse, Dual Rinse)
9KW - 150°F incoming water raised to 185°F (35°F rise) (180°F minimum)
Blower Dryer Heat Pump Technology
Steam Heat Requirements
Steam Consumption
Tank Heat - Pounds per hour - maximum
(Regulated) - based on 10 to 45 PSI steam at
the machine
179 lbs./150°F Wash minimum - 160°F Rinse minimum -
160°F Dual Rinse minimum
Peak Rate of Drain Flow — Gallons per minute
Initial rate with full tanks 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
FT (ight type) Models—many additional variations of
these model specications are available. Engineering
data furnished on request. Numbers in parentheses,
after model number from left to right, represent length
in feet of the following respectively; Loading section,
Washing and Power Rinsing sections, Unloading
section.
F40352 (REV. 02/15) LITHO IN U.S.A. (H-01)