Hobart FT1000 Dishwasher User Manual


 
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 9 of 12
GENERAL NOTES:
(a)
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
A
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
T
AP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMAT
ION
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
FT1000
STEAM L-R
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 40-45 PSI.
(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO
THE
DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F
CONTACT SALES ENGINEERING.
(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
WATER SUPPLY LINES AT SERVICE CONNECTION.
(e) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE
AT THE DISHWASHER, CONTACT SALES ENGINEERING.
PLUMBING CONNECTIONS:
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,
1" FPT, 5-1/2" AFF see notes (c) AND (d).
P3 COMMON DRAIN CONNECTION.
TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END
OF UNIT, PLUG OPPOSITE END.
2" FPT. 7" AFF
P4 COMMON STEAM CONNECTION (TANK HEAT)
1-1/2" FPT, 4-3/8"
AFF (10-45 PSI FLOWING PRESSURE) see note (e).
P5 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS.
3/4" FPT, 11" AFF
VENTILATION NOTES:
(f) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
VENTILATION REQUIREMENTS:
V1 IF SUPPLEMENTAL VENTILATION IS REQUIRED TO HANDLE MACHINE’S
LATENT & SENSIBLE HEAT:
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF
PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD
SUPPLIED AND INSTALLED BY OTHERS). WHEN VENT HOOD IS INSTALLED,
BACK DRAFT PREVENTER IS REQUIRED (SUPPLIED AND INSTALLED BY OTHERS)
.
95-3/8" AFF
ELECTRICAL CONNECTIONS
COMMON ON ALL MODELS:
E1 ELECTRIC CONNECTION, DETERGENT
AND RINSE FEEDERS (MACHINE
SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS)
1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AF
F
E4
ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK
A
UX HEAT (13 KW), 1" CONDUIT. 79-1/8" AFF
E5
ELECTRIC CONNECTION, ELECTRIC BOOSTER, 9KW.
1" CONDUIT. 79-1/8" AFF
MODEL NO.
"A" "B"
"C"
NO
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
FT1023 (7.5'-8'-7.5') 23' 3-1/2"
FT1024 (8.5'-8'-7.5') 24' 3-1/4"
FT1025 (9.5'-8'-7.5') 25' 3-3/32"
FT1025 (7.5'-8'-9') 24' 11-1/4"
FT1026 (8.5'-8'-9')
25' 11"
FT1027 (9.5'-8'-9') 26' 10-27/32"
FT1027 (7.5'-8'-11') 26' 10-7/8"
FT1028 (8.5'-8'-11') 27' 10-5/8"
FT1029 (9.5'-8'-11') 28' 10-15/32"
FT1030 (7.5'-8'-15') 30' 6-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16"
FT1032 (9.5'-8'-15') 32' 5-25/32"
FT1032 (7.5'-8'-17') 32' 5-3/4"
FT1033 (8.5'-8'-17') 33' 5-1/2"
FT1034 (9.5'-8'-17') 34' 5-11/32"
MODEL:
FT1000
ADVANSY
S
STEAM
L-R OPER
ATION
00-949509
REV A1
ELECTRICAL CONNECTIONS
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, 1-1/4" CONDUIT.
79-1/8" AFF
E9 ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK AUX
HEAT (13 KW), & ELECTRIC BOOSTER (9 KW), 1" CONDUIT, 79-1/8" AFF
SERVICE CONNECTION W/O CIRCUIT BREAKERS
(3) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS AND CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45 45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
64.2 80 80
480/60/3
30.0 40 40
HEAT PUMP COMPRESSOR & WASH TANK AUX HEAT (13 KW)
(1) CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
25.8
35 35
480/60/3
12.9 20 20
ELECTRIC BOOSTER
(1) 9 KW CONNECTION AS SHOWN BELOW
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS & CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45
45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
91.2 125 125
480/60/3
42.9 60 60
HEAT PUMP COMPRESSOR, WASH TANK AUX HEAT (13 KW)
& ELECTRIC BOOSTER (9 KW)
(1) CONNECTION AS SHOWN BELOW