ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED
WITH A FOUR-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE CONNECTED
INTO A PROPERLY GROUNDED FOUR-PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT
THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE
GROUNDING PRONG FROM THIS PLUG.
The electrical diagram is located in an envelope behind the control panel.
For Hard-Wired Ovens
Have a qualified electrician wire the oven into a properly rated dedicated circuit, connecting to the wires
and conduit provided. Use appropriate conduit, strain relief, wire and connectors. Care should be
taken not to damage the wire when applying setscrew type connectors. If connecting to aluminum
wiring, properly installed connections listed for use with aluminum and copper wiring must be used.
For Cord-Connected Ovens
A short power supply cord is provided to reduce the risks resulting from becoming entangled in or
tripping over a longer cord. Do not use an extension cord.
Plug the oven into a dedicated circuit outlet of the appropriate NEMA style and rating. The wall outlet
receptacle recommended for this appliance is NEMA 14 - 30R.
NOTE: Both hot legs must measure 120V to neutral. Do not connect this oven to a source using a
stinger
or
wild leg
.
NEMA 14 - 30R Wall receptacle
30 Amp
Single Phase 4 Wire Ground with Neutral
ELECTRICAL DATA
Voltage Amp KW Cycles Phase
120/208-240 30 6.5 60 1