Hobart ML-114625 Fryer User Manual


 
— 8 —
I
Place fryer as near to its final position as possible. Connect 3 phase line to X, Y and Z of terminal block.
To reach terminal block, remove electric cover plate from fryer.
For each 15
1
2" (39.3 cm) and 21" (53.3 cm) section, a 3 phase supply line capable of handling the
required KW at the fryer's rated voltage (208, 240, 480) is needed. Refer to the fryer data plate for this
electrical information.
If a fan interlock is needed, it should be connected to 1 and 2 on the 4 pole barrier strip. 1 and 2 go
to a set of dry contacts on the power switch.