LOCATION
The HO300G and HO300E Mini Rotating Rack Ovens must have the following minimum clearances
to combustibles:
Back and sides: 0"
Bottom: 0"
Top: 18" (45.7 cm)
Be sure that electrical, water and drain connections are accessible and can be made per local and
national codes. The equipment area must be kept free and clear of combustible substances.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the
combustion chamber must be provided. Make sure there is an adequate supply of air in the room to
replace air taken out by the ventilating system.
INSTALLATION CODES AND STANDARDS
The oven must be installed in accordance with:
In the United States of America:
1. State and local codes.
2.
National Fuel Gas Code
, ANSI-Z223.1 (latest edition). Copies may be obtained from The
American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3.
National Electrical Code
, ANSI/NFPA-70 (latest edition).
In Canada:
1. Local codes.
2. CAN/CGA-B149.1
Natural Gas Installation Code
(latest edition).
3. CAN/CGA-B149.1
National Fuel Gas Code
(latest edition), available from The Canadian Gas
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.