Hobart OV500G1 ML- 132500 Double Oven User Manual


 
OV500 SERIES RACK OVEN - REMOVAL AND REPLACEMENT OF PARTS
4. Remove screws securing burner cover to oven.
5. Remove all screws securing gas manifold to
burner rack assembly.
6. Disconnect the gas supply union fitting from gas
manifold assembly.
7. Pull gas manifold from burner rack assembly.
8. Remove orifice fitting from gas manifold.
NOTE: Note orifice size for natural or L.P.
9. Reverse the procedure to install.
HEAT EXCHANGER
A. CHECK ALL JOINTS PRIOR TO THE
GAS VALVE (SOLENOID) BEFORE
LIGHTING UNIT.
B. CHECK ALL JOINTS AFTER TO THE
GAS VALVE (SOLENOID) AFTER THE
UNIT IS LIT.
1. Open control compartment door to gain access
to burner assembly.
2. Remove screws securing burner cover to oven.
3. Disconnect gas manifold at the union fitting
OV500G1 & OV500G2.
4. Disconnect flame sensor lead wire OV500 G1 &
OV500G2.
F25361 (January 2010)Page 19 of 60