Hobart OV500G1 ML- 132500 Double Oven User Manual


 
OV500 SERIES RACK OVEN - REMOVAL AND REPLACEMENT OF PARTS
To install:
1. Install high limit in component box or service
entrance box.
2. Connect lead wires to high limit.
3. Route high limit capillary tube to top of oven.
4. Mark 12" from end of probe.
5. Insert male compression fitting onto high limit
probe.
6. Install female fitting into center probe location.
7. Insert 12" of high limit probe into oven. Ensure
that high limit probe goes through both inner
and outer walls of oven.
NOTE: Remove vent lid to aid in feeling for high limit
probe protruding down through oven.
8. Install first set of 3 spacers into high limit fitting.
9. Pack seal gasket material around probe into
high limit fitting.
10. Insert second set of 3 spacers into high limit
fitting.
11. Tighten male compression fitting against
second set of spacers to secure high limit
probe.
12. Install probe cover.
13. Check oven for proper operation.
DRAFT INDUCER MOTOR
1. Access draft inducer box from top of oven.
2. Remove vacuum line from fitting on draft
inducer housing.
3. Remove screws securing draft inducer exhaust
duct & collar to hood.
4. Remove screws securing draft inducer cover to
box.
5. Remove screws securing draft inducer motor
(flex) conduit clamps from oven.
6. Remove screws securing draft inducer box and
lift box from oven.
F25361 (January 2010)Page 23 of 60