Hobart QEH Mixer User Manual


 
– 9 –
CONTROLS — Thaw Proofer (Fig. 13)
Thaw Proofer
TEMP
SET VIEW
F
SET
%
HUM TIMER
SET
START
SET THAW
PROOF
AUTOMATIC
MODE
ON
OFF
Fig. 13
Press
MODE
and
or
to select Proof, Set Thaw, or Automatic mode.
The mode lights indicate control function
:
MANUAL PROOF mode allows you to set Temperature, Humidity, and
Time values for manual or automatic proofing operations. To start
a manual (non-timed) proofing operation, press
STAR
T
. To set
Proofer values, refer to page 8.
S
ET THAW mode allows you to set Temperature, Humidity, and Time
values for the Preheat and Thaw portions of an Automatic cycle
without disturbing an ongoing proofing operation. Thaw values are
set the same as Proofer values — refer to page 8. Control returns
to manual Proof mode if no buttons are pressed in 30 seconds. To
enter Set Thaw mode, the timer must not be running.
A
UTOMATIC PREHEAT — displays Thaw Temperature and Thaw
Humidity. Thaw Temperature flashes when reached, indicating
ready-to-load. Load the product and press
STAR
T
to begin an
Automatic Thaw and Proof cycle.
A
UTOMATIC THAW — maintains the Thaw Temperature and Thaw
Humidity while the Thaw Time counts down. After the Timer counts
down to zero, the control immediately goes into Automatic Proof.
AUTOMATIC PROOF — maintains the Proof Temperature and Proof
Humidity while the Proof Time counts down. After the Timer counts
down to zero, the control beeps and the display flashes indicating
that the product is ready to be unloaded from the proofer and moved
to an oven for baking. The control returns to manual Proof mode.
During Automatic mode —
To cancel the Thaw portion of an Automatic cycle, press Timer Set and advance to the Proof portion.
To cancel the entire Automatic Thaw and Proof cycle, press the Mode button and return to manual Proof.