F. Water Supply and Drain Connections
WARNING
1. Water supply and drain connections must be installed in accordance with
applicable national, state, and local regulations.
2. Normal operating water temperature should be within 45°F to 90°F (7°C
to 32°C). Operation of the icemaker, for extended periods, outside of this
normal temperature range may affect icemaker performance.
3. To prevent damage to equipment, do not operate the icemaker when the
water supply is off, or if the pressure is below 7 PSIG. Do not run the
icemaker until the proper water pressure is reached.
•Aplumbingpermitandservicesofalicensedplumbermayberequiredinsomeareas.
•Externallters,strainers,orsoftenersmayberequireddependingonwaterquality.
Contact your local Hoshizaki distributor for recommendations.
•Watersupplyinletis1/2"femalepipethread(FPT).
•Awatersupplylineshut-offvalveanddrainvalveshouldbeinstalled.Aminimumof
1/4"nominalIDcopperwatertubingorequivalentisrequiredforthewatersupplyline.
•Watersupplypressureshouldbeaminimumof7PSIGandamaximumof113PSIG.If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
•Drainoutletis1/2"FPT.Aminimumof1/2"nominalIDhardpipeorequivalentis
required for the drain line.
•Drainlineshouldnotbepipeddirectlytothesewersystem.Anairgapofaminimumof
2 vertical inches (5 cm) should be between the end of the drain pipe from the icemaker
and the oor drain.
•Forgravitydraininstallation,drainmusthave1/4"fallperfoot(2cmper1m)on
horizontal runs to get good ow. A vented tee connection is also required for proper
ow.
•Foroptionaldrainpumpinstallation,refertotheinstructionmanualincludedwiththe
pump.
Fig. 30
Piping to approved drain.
Leave a 2-inch (5-cm) vertical
air gap between the end of the
pipe and the drain.
2-inch (5-cm)
air gap
Floor
Drain
Water Supply Line
Shut-OffValve
Water Supply Line
DrainValve
Water Supply Inlet
1/2"FPT
Drain Outlet
1/2"FPT
VentedTee
Connection
Minimum1/4"NominalIDCopperWaterTubing
Minimum1/2"NominalIDHardPipe