Hoshizaki C-100BAF Ice Maker User Manual


 
32
1. Storage Bin Drain
In some conditions, slime may build up inside the storage bin drain and prevent water
from draining properly. To prevent this buildup, perform the following procedure once
every 3 months or as often as necessary for conditions.
1)Movethepowerswitchtothe"OFF"position.
2) Remove all ice from the storage bin.
3) Mix a batch of sanitizing solution by diluting 1.25 . oz. (37 ml or 2.5 tbs) of a
5.25% sodium hypochlorite solution (chlorine bleach) with 2.5 gallons (9.5 l) of
warm water. Using a chlorine test strip or other method, conrm that you have a
concentration of about 200 ppm.
4) Slowly pour the sanitizing solution into the storage bin.
5) After all of the solution has drained, clean the storage bin liner with a neutral cleaner.
Rinse thoroughly with clean water.
6)Movethepowerswitchtothe"ON"positiontostarttheautomaticicemakingprocess.
2. Condenser
Check the condenser once a year, and clean if required by following the steps below.
More frequent cleaning may be required depending on location.
WARNING
1.Movethepowerswitchtothe"OFF"positionandunplugtheunitfromthe
electrical outlet before cleaning the condenser.
2. Condenser ns are sharp. Use care when cleaning.
1)Movethepowerswitchtothe"OFF"positionandunplugtheunitfromtheelectrical
outlet.
2) Remove the 2 screws securing the front
panel, then remove the panel. See Fig. 33.
3) Remove the 2 screws securing the louver,
then remove the louver.
4) Use a brush attachment on a vacuum
cleaner to gently clean the condenser ns.
Do not use too much force, otherwise the
ns could be damaged.
5) Replace the louver and front panel in their
correct positions. Ensure that the screws
are securely in place.
6)Plugtheunitbackin.Movethepowerswitchtothe"ON"positiontostarttheautomatic
icemaking process.
Front Panel
Louver
Fig. 33
Screws
Screws
Condenser