7. Removal and Replacement of Control Water Valve
1) Unplug the icemaker.
2) Remove the panels.
3) Close the water supply line shut-off valve.
4) Disconnect the terminal from the control water valve.
5) Loosen the fitting nut on the control water valve inlets, and remove the control water
valve. Do not lose the packings inside the fitting nut.
6) Remove the water supply hose from the control water valve.
7) Install the new control water valve.
8) Assemble the removed parts in the reverse order of the above procedure.
9) Open the water supply line shut-off valve.
10) Check for water leaks.
11) Replace the panels in their correct position.