Hoshizaki FD-1001MAH(-C) Refrigerator User Manual


 
51
APPROXIMATE Ambient Water Temp. (°F)
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70
*940 *(427)
890
(405)
855
(389)
80 820
(373)
790
(358)
755
(344)
90 725
(330) *695 *(317)
670
(304)
lbs./day (kg/day) 100 640
(292)
615
(280) *580 *(265)
APPROXIMATE ELECTRIC 70
*1404
-- 1402 -- 1400 --
CONSUMPTION 80 1398 -- 1395 -- 1393 --
90 1391 --
*1389
-- 1372 --
watts 100 1354 -- 1337 --
*1319
--
APPROXIMATE WATER 70
*113 *(427)
107
(405)
103
(389)
CONSUMPTION PER 24 HR. 80 99
(373)
95
(358)
91
(344)
90 87
(330) *84 *(317)
80
(304)
gal./day (l/day)
100 77
(292)
74
(280) *70 *(265)
EVAPORATOR OUTLET TEMP. 70
*17 *(-9)
17
(-9)
17
(-9)
80 17
(-9)
14
(-10)
14
(-10)
90 14
(-10) *14 *(-10)
12
(-11)
°F (°C) 100 12
(-11)
12
(-11) *12 *(-11)
HEAD PRESSURE 70
*304 *(21.4)
304
(21.4)
304
(21.4)
80 287
(20.1)
287
(20.1)
287
(20.1)
90 269
(18.9) *269 *(18.9)
269
(18.9)
PSIG (kg/cm²G)
100 204
(14.3)
204
(14.3) *204 *(14.3)
SUCTION PRESSURE 70
*39 *(2.7)
39
(2.7)
39
(2.7)
80 37
(2.6)
37
(2.6)
37
(2.6)
90 36
(2.5) *36 *(2.5)
36
(2.5)
PSIG ( kg/cm²G )
100 31
(2.2)
31
(2.2) *31 *(2.2)
TOTAL HEAT OF REJECTION 8800 BTU/h (AT 90°F /WT 70°F)
50 70 90
Note: We reserve the right to make changes in specications and design without prior
notice.
2. FD-1001MAH-C (air-cooled)